Molded Case Motor Circuit Protector, Ex9M3M Series
400 A frame size, 3 Poles
N Interrupting, Lug Line/ Load Side, 400A
Part number: 1101496

Full load Current at Cam Setting A 96.2 to 115.3A, Cam Setting B 115.4 to 134.5A, Cam Setting C 134.6 to 153.7A, Cam Setting D 153.8 to 173.0A, Cam Setting E 173.1 to 192.2A, Cam Setting F 192.3 to 211.4A, Cam Setting G 211.5 to 217.6A

Motor Circuit Protection (MCP) Trip Setting at Cam Setting A – 1250, Motor Circuit Protection (MCP) Trip Setting at Cam Setting B 1500, Motor Circuit Protection (MCP) Trip Setting at Cam Setting C 1750, Motor Circuit Protection (MCP) Trip Setting at Cam Setting D 2000, Motor Circuit Protection (MCP) Trip Setting at Cam Setting E 2250, Motor Circuit Protection (MCP) Trip Setting at Cam Setting F 2500, Motor Circuit Protection (MCP) Trip Setting at Cam Setting G 2750. Rated Current at 480 Vac – 35kA

Part number: 1101998

Features:
The traditional system used for this purpose is based on three different devices: a circuit breaker for protection against short-circuit, a thermal relay for protection against overload and phase loss or unbalance of phase, and a contactor for motor switching.
In particular, when selecting these devices, different factors must be taken into consideration, such as:
The motor power
The diagram and type of starting
The type of motor: with cage rotor or with wound rotor
The fault current at the point of the network where the motor is installed
Offers a complete range of 3 pole Molded Case Motor Circuit Protectors (MCPs, magnetic or short circuit protection only) which are used to protect the cables feeding three phase motors in six frame sizes: M1M – 150 A, M2M – 250 A, M3M – 400 A, M4M – 600 A, M5M – 800 A, and M6M – 1200 A. Each frame size offers a range of interrupting ratings at 240-690 Vac and 250-600 Vdc. 5-Year limited warranty.

Certifications:
UL 489 Recognized, File Number E355392 (Standard for connection terminals which allows the user to apply field wiring directly to the breaker)
Certified for Canada According to CSA Standards 22.2 No.5
IEC/EN 60947-2
CE Compliant
RoHS Compliant